Summary

MDPCT1is a four-layer cos-theta Nb <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">3</sub> Sn dipole demonstrator developed and tested at FNAL in the framework of the U.S. Magnet Development Program. The magnet reached record fields for accelerator magnets of 14.1 T at 4.5 K in the first test and 14.5 T at 1.9 K in the second test and then showed large degradation. While its inner coils performed exceptionally well with only two quenches up to 14.5 T and no evidence of degradation, the outer coils degraded over the course of testing. By adopting new measurement and analysis techniques at FNAL we are discussing in detail what happened. Both success and failure in our diagnostics are discussed. The evolution of techniques over the course of two